Sikadur®-42 MP Slow
Sikadur®-42 MP Slow is a three-component, multipurpose, moisture tolerant, epoxy grouting system. Suitable for use in hot and tropical climatic conditions.
- High early strength
- Ready-to-mix, pre-batched units
- Moisture tolerant
- Non-shrink
- Corrosion and chemically resistant
- Stress and impact resistant
- High compressive strength
- High vibration resistance
- Low coefficient of thermal expansion
Usage
High-strength grouting and fixing of:- Starter bars
- Anchors
- Fasteners
- Tie rods
- Crash barrier posts
- Fence and railing posts
- Base plates
- Machine bases, seat base-plates for light and heavy machinery including heavy impact and vibratory machinery, reciprocating engines, compressors, pumps, presses, etc.
- Bridge bearings
- Mechanical joints (i.e. road/bridge/deck types etc.)
- Crane tracks
- Light rail and permanent way in tunnels
- Light rail and permanent way over bridges
Advantages
- High early strength
- Ready-to-mix, pre-batched units
- Moisture tolerant
- Non-shrink
- Corrosion and chemically resistant
- Stress and impact resistant
- High compressive strength
- High vibration resistance
- Low coefficient of thermal expansion
Packaging
Standard unit: 28 kg, 24 kg and 70 kg
Component: A | Component: B | Component: C | Component: A+B+C |
3.34 kg | 0.66 kg | 24 kg | 28 kg |
3.34 kg | 0.66 kg | 20 kg | 24 kg |
8.35 kg | 1.65 kg | 2 x 30 kg | 70 kg |
Bulk packaging: 140 kg and 120 kg unit
Component: A | Component: B | Component: C | Component: A+B+C |
16.7 kg | 3.3 kg | 5 x 24 kg = 120 kg | 140 kg |
16.7 kg | 3.3 kg | 5 x 20 kg = 100 kg | 120 kg |
Colour
Concrete Grey
Product Details
CERTIFICATES AND TEST REPORTS
- Testing according to EN 1504-6.
Composition
Epoxy resin
Shelf life
Component A | 24 months from the date of production |
Component B | 24 months from the date of production |
Component C | 12 months from the date of production |
Storage conditions
Stored properly in original, unopened, sealed and undamaged packaging in dry conditions at temperatures between +5 °C and +30 °C. Protect from direct sunlight, heat and moisture.
Density
~2 130 kg/m3 (A+B+C) |
Effective bearing area
> 90 % | (ASTM C1339) |
Compressive strength
Curing time | Curing temperature | ||
+23 °C | +30 °C | +40 °C | |
1 day | ~74 N/mm2 | ~80 N/mm2 | ~89 N/mm2 |
3 days | ~80 N/mm2 | ~87 N/mm2 | ~94 N/mm2 |
7 days | ~95 N/mm2 | ~96 N/mm2 | ~99 N/mm2 |
28 days | ~100N/mm2 | ~103N/mm2 | ~105N/mm2 |
Product cured and tested at temperatures indicated.
Test specimen size: 50 * 50 * 50 mm
Modulus of elasticity in compression
~20 000 N/mm2 | (ASTM D695-96) |
Flexural-strength
~37 N/mm2 |
~42 N/mm2 |
~32 N/mm2 |
Modulus of elasticity in flexure
~15 000 N/mm2 | (EN 53452) |
Tensile strength
~15 N/mm2 |
~18 N/mm2 |
~15 N/mm2 |
Tensile adhesion strength
> 36 N/mm2 (concrete failure) (slant shear) |
~11 N/mm2 (on steel) |
> 3.5 N/mm2 (concrete failure) |
Creep
0.9 % at 4.14 N/mm2 (600 psi) / 31 500 N (+60 °C) |
0.11 % at 2.76 N/mm2 (400 psi) / 21 000 N (+60 °C) |
API requirements: ≤ 0.5 % with 2.76 N/mm2 load
Heat deflection temperature
+54 °C (7 d / +23 °C) | (ISO 75) |
Shrinkage
–0.032 % |
–0.02 % |
Coefficient of thermal expansion
2.1 x 10–5 [1/°C] or [1/K], (-30 °C to +30 °C) |
3.8 x 10–5 [1/°C] or [1/K], (+24 °C to +100 °C) |
2.6 x 10–5 [1/°C] or [1/K], (-20 °C to +60 °C) |
Service temperature
-40 °C to +60 °C
Thermal compatibility
No delamination / pass | (ASTM C884) |
Water absorption
0.055% (7 d) (coefficient W) | (ASTM C413) |
Application
Layer thickness
Minimum grout depth: 10 mm
Maximum grout depth: 150 mm
Temperature | Layer thickness max. |
20 °C – 30 °C | 150 mm |
30 °C – 40 °C | 100 mm* |
* no reduction of fillers; apply only with Mixing Ratio A : B : C = 5 : 1 : (30 - 36)
Peak exotherm
41 °C (at +23 °C) | (ASTM D 2471) |
Material temperature
Sikadur®-42 MP Slow must be applied at temperatures between +20 °C and +35 °C
Condition the material by also storing at this temperature for 48 hours before use.
Ambient air temperature
+20 °C min. / +40 °C max.
Mixing ratio
28 kg unit, 70 kg unit and 140 kg unit
Component A : B : C = 5 : 1 : 36 by weight
Liquid (A+B) / solid (C) = 1 : 6 by weight
24 kg unit and 120 kg unit
Component A : B : C = 5 : 1 : 30 by weight
Liquid (A+B) / solid (C) = 1 : 5 by weight
Dew point
Substrate temperature during application must be at least 3 °C above dew point to avoid condensation.
Substrate temperature
+20 °C min. / +40 °C max.
Substrate moisture content
≤ 4 % pbw
Pot Life
(200 g, adiabatic testing)
+23 °C | +40 °C | |
5 : 1 : 30 | 100 – 110 min | 45 – 50 min |
The potlife begins when the resin and hardener are mixed. It is shorter at high temperatures and longer at low temperatures. The greater the quantity mixed, the shorter the potlife. To obtain longer workability at high temperatures, the mixed adhesive may be divided into portions. Another method is to chill components A+B and C before mixing them (i.e. only when application temperatures are above +20 °C).
SUBSTRATE QUALITY
Mortar and concrete must be older than 28 days (dependent on minimum strength requirements).
Verify the substrate strength (concrete, natural stone etc.).
The substrate surface (all types) must be clean, dry and free from contaminants such as dirt, oil, grease, existing surface treatments and coatings etc.
Steel substrates must be de-rusted to a standard equivalent to Sa 2.5.
The substrate must be sound and all loose particles must be removed.
Substrate must be dry or mat damp and free from any standing water, ice etc.
SUBSTRATE PREPARATION
Concrete, mortar, stone
Substrates must be sound, dry, clean and free from laitance, ice, standing water, grease, oils, old surface treatments or coatings and all loose or friable particles must be removed to achieve a laitance and contaminant free, open textured surface.
Steel
Must be cleaned and prepared thoroughly to an acceptable quality standard equivalent to SA 2.5 i.e. by blastcleaning and vacuum. Avoid dew point conditions.
Surface and base plate contact area must be clean and sound. For best results, the substrate shall be dry. Remove dust, laitance, oils, grease, curing compounds, impregnations, waxes, foreign particles, coatings, and disintegrated materials by mechanical means, i.e. chipping with a chisel, blastcleaning etc.
All anchor pockets or sleeves must be free of water. Apply grout immediately to prevent re-oxidizing / rust formation.
For optimum results:
When grouting areas or equipment that is sensitive to vibration, it is recommended that the contact surfaces are prepared according to the latest edition of the American Petroleum Institute’s Recommended Practice 686 “Machinery Installation and Installation Design”, Chapter 5.
MIXING
Pre-batched units
Mix components A and B in the component A pail for approximately 30 – 60 seconds with a paddle attached to a low speed drill (300 – 450 rpm). Avoid aeration while mixing until the material becomes uniformly blended in colour and viscosity. Place the mixed epoxy into an appropriate mixing vessel. Slowly add the contents of component C (to keep air entrapment at a minimum) dependent on flow requirements (observe the correct mixing ratio) and mix until uniform and homogeneous. (approximately 3 minutes)
Mix only that quantity which can be used within its potlife.
Bulk packing (not pre-batched)
First, stir each component thoroughly. Add the components in the correct proportions into a suitable mixing pail. Mix the components. Use an electric low speed mixer etc as above for the pre-batched units.
Never mix component A and B without adding component C (as the exothermic reaction between A and B alone generates excess heat)
Leave Sikadur®-42 MP Slow to stand in the normal mixing vessel until the majority of entrained air bubbles have dispersed.
CLEANING OF EQUIPMENT
Sweep excess grout into appropriate containers for disposal before it has hardened.
Dispose of in accordance with applicable local regulations. Uncured material can be removed with Sika Colma Cleaner. Cured material can only be removed mechanically.