Sikaplan® WP 1100-15 HL
Sikaplan® WP 1100-15 HL is a flexible, homogeneous sheet waterproofing membrane with a signal layer based on premium-quality polyvinylchloride (PVC-P). Suitable for use in hot and tropical climatic conditions.
- Based on virgin material with consistent quality
- Without DEHP (DOP) plasticisers
- With signal layer to indicate damages
- Optimized flexibility, tensile strength and multi-axial elongation
- Elastic material behaviour
- Flexible in cold temperatures
- Suitable for contact with acidic soft water and alkaline environments
- Resistant to root penetration and micro-organisms
- Optimized workability, thermally weldable
- Can be installed on damp substrates
- Temporary UV stability for installation
Contact us if document is not available
Usage
Waterproofing of tunnels and basements against water ingress.Advantages
- Based on virgin material with consistent quality
- Without DEHP (DOP) plasticisers
- With signal layer to indicate damages
- Optimized flexibility, tensile strength and multi-axial elongation
- Elastic material behaviour
- Flexible in cold temperatures
- Suitable for contact with acidic soft water and alkaline environments
- Resistant to root penetration and micro-organisms
- Optimized workability, thermally weldable
- Can be installed on damp substrates
- Temporary UV stability for installation
Packaging
Roll size | 2.20 m (width) x roll length 20 m or individual as specified |
Colour
Surface | Smooth |
Colour | Signal layer: Yellow Bottom layer: Dark grey |
Product Details
APPROVALS / CERTIFICATES
- 'Polymeric geosynthetic barrier for use in tunnels and underground structures. Fluid barrier.' according to EN 13491, Declaration of Performance Nr. 0207042010001500001003, certified by notified factory production control certification body 1213, certificate of conformity of the factory production control 1213-CPR-028, and provided with the CE marking.
- 'Flexible sheets for waterproofing - Plastic and rubber damp proof sheets including plastic and rubber basement tanking sheet' according to EN 13967, Declaration of Performance Nr. 0207041010001500001003, certified by notified factory production control certification body 1213, certificate of conformity of the factory production control 1213-CPD-029, and provided with the CE marking.
Shelf life
5 years shelf life from date of production if stored properly in undamaged, unopened, original sealed packaging
Storage conditions
Rolls must be stored in their original packaging, in a horizontal position and in cool and dry conditions. They shall be protected from direct sunlight, rain, snow and ice, etc. Do not stack pallets of rolls during transport or storage.
Effective Thickness
1.50 mm (-5 % / +10 %) including signal layer | (EN 1849-2) |
Mass per unit area
1.95 kg/m2 (-5 % / +10 %) | (EN 1849-2) |
System Structure
Ancillary products:
- Sikaplan® WP Disc
- Sikaplan® W Felt PP
- Sikaplan® WP Protection Sheets
- Sika Waterbar® (PVC-p based)
- Sikaplan® WP Tape System
- Sika® Dilatec® System
For detailed information regarding system structure please refer to the method statement.
Tensile Strength
17.0 (± 2.0) N/mm2 (machine direction) 16.0 (± 2.0) N/mm2 (cross direction) | (EN 12311-2) |
Resistance to Static Puncture
1.75 kN (± 0.25) kN | (EN ISO 12236) |
Resistance to Impact
Watertight at 450 mm drop height | (EN 12691) |
(500 g falling weight, Method A) |
Foldability at Low Temperature
No cracks at -20 °C | (EN 495–5) |
Dimensional Change after Heat
Dimensional change | < 2.0 % (machine/ cross direction) |
No blisters
Behaviour after Storage in Warm Water
Change of mass | < 10 % |
Microbiological Resistance
Change of tensile strength | ≤ 15 % |
Change in elongation | ≤ 15 % |
Resistance to Weathering
Remaining tensile strength and elongation: | ≥ 75 % |
Reaction to Fire
Class E | (EN 13501-1) (EN 11925-2) |
Behaviour after Heat Welding of Overlaps
Shear resistance of welded seam | Break occurs outside of seam |
Peel resistance of welded seam | ≥ 6.0 N/mm |
Service Temperature
-10 °C min. / +35 °C max.
Ambient Maximum Temperature of Liquids
+35 °C
Application
Ambient Air Temperature
+5 °C min.
SUBSTRATE QUALITY
In-situ concrete: Steel-trowel finished, clean, sound and free of standing/running water, homogeneous, free from oils and grease, dust and loose or friable particles.
Shotcrete: The profile of the shotcrete surface must not exceed a ratio of length to depth of 5:1 and its minimum radius must be 20 centimetre. The shotcrete surface must not contain broken aggregates. Any leaks must be sealed with Sika® waterproof plugging mortar, or drained with a Sika® FlexoDrain system. Where necessary to achieve the desired profile/surface, apply a fine sprayed concrete layer on the shotcrete surface with a minimum thickness of 3 to 5 centimetre and aggregate diameter not exceeding 8 millimetre. Steel (girders, reinforcement mesh, anchors, etc.) must also be covered with a minimum of 4 centimetre fine sprayed concrete. The shotcrete surface must be clean (no loose stones, nails, wires, etc.).
A polypropylene geotextile (≥ 350 g/m2) or a compatible drainage layer must also be installed prior to the Sikaplan® WP 1100-15 HL membrane installation.
For detailed information regarding substrate quality please refer to the method statement.