Contact us if document is not available
Sikaplan® WP 1100-22 HL
Sikaplan® WP 1100-22 HL is a flexible, homogeneous sheet waterproofing membrane with a signal layer, based on premium-quality polyvinylchloride (PVC-P). Suitable for use in hot and tropical climatic conditions.
- High resistance to ageing
- Based on virgin material with consistent quality
- Without DEHP (DOP) plasticisers
- With signal layer to indicate damages
- Optimized flexibility, tensile strength and multi-axial elongation
- Elastic material behaviour
- High resistance to mechanical influences
- Flexible in cold temperatures
- Suitable for contact with acidic soft water and alkaline environments
- Resistant to root penetration and micro-organisms
- Optimized workability, thermally weldable
- Can be installed on damp substrates
- Temporary UV stability for installation
- Self-extinguishing in fire
Contact us if document is not available
Usage
Waterproofing of tunnels and basements against water ingressAdvantages
- High resistance to ageing
- Based on virgin material with consistent quality
- Without DEHP (DOP) plasticisers
- With signal layer to indicate damages
- Optimized flexibility, tensile strength and multi-axial elongation
- Elastic material behaviour
- High resistance to mechanical influences
- Flexible in cold temperatures
- Suitable for contact with acidic soft water and alkaline environments
- Resistant to root penetration and micro-organisms
- Optimized workability, thermally weldable
- Can be installed on damp substrates
- Temporary UV stability for installation
- Self-extinguishing in fire
Packaging
Roll size | 2.20 m (width) × roll length individual as specified |
Colour
Surface | Smooth |
Colour | Signal layer: Yellow Bottom layer: Dark grey |
Product Details
APPROVALS / CERTIFICATES
- 'Polymeric geosynthetic barrier for use in tunnels and underground structures. Fluid barrier.' according to EN 13491, Declaration of Performance Nr. 0207042010002200001003, certified by notified factory production control certification body 1213, certificate of conformity of the factory production control 1213-CPR-028, and provided with the CE marking.
- 'Flexible sheets for waterproofing - Plastic and rubber damp proof sheets including plastic and rubber basement tanking sheet' according to EN 13967, Declaration of Performance Nr. 0207041010002200001003, certified by notified factory production control certification body 1213, certificate of conformity of the factory production control 1213-CPD-029, and provided with the CE marking.
Shelf life
5 years shelf life from date of production if stored properly in undamaged, unopened, original sealed packaging
Storage conditions
Rolls must be stored in their original packaging, in a horizontal position and in cool and dry conditions. They must be protected from direct sunlight, rain, snow and ice, etc.
Do not stack pallets of rolls during transport or storage.
Visible Defects
Pass | (EN 1850-2) |
Effective Thickness
2.20 mm (-5 / +10 %) including signal layer | (EN 1849–2) |
Mass per unit area
2.81 kg/m2 (-5 / +10 %) | (EN 1849–2) |
System Structure
Ancillary Products:
- Sikaplan® WP Disc
- Sikaplan® W Felt PP
- Sikaplan® W Tundrain
- Sikaplan® WP Protection Sheets
- Sika Waterbar® (PVC-p based) for forming compartments, waterproofing of concrete joints and fixations
- Sikaplan® WP Tape System
- Sika® Dilatec® System
For detailed information regarding system structure please refer to the method statement.
Tensile Strength
17.0 N/mm2 (± 2.0) (machine direction) | (ISO 527) |
16.0 N/mm2 (± 2.0) (cross direction) |
Burst Strength
≥ 80 % (D = 1.0 m) | (EN 14151) |
Resistance to Impact
Watertight at 750 mm drop height | (EN 12691) |
(500 g falling weight, Method A) |
Long Term Compression Strength
Watertight at 7.0 N/mm2 (50 h) | (Similar to SIA V280/14) |
Foldability at Low Temperature
No cracks at -20 °C | (EN 495–5) |
Dimensional Change after Heat
Dimensional change: | < 2.0 % (machine/cross direction) |
Resistance to Oxidation
Change in elongation: | ≤ 10 % |
Change of tensile strength: | ≤ 10 % |
Behaviour after Storage in Warm Water
Change of tensile strength: | < 20 % (machine/ cross) |
Change in elongation: | < 20 % (machine/ cross) |
Change of mass: | < 4 % |
Change of mass: | < 10 % |
Chemical Resistance
Saturated Limewash (Test Liquid 2)
Reduction of tensile strength and elongation | ≤ 20 % |
5 – 6 % Sulfurous acid (Test Liquid 3)
Reduction of tensile strength and elongation | ≤ 20 % |
Foldability at low temperatures | No cracks at -20 °C |
Microbiological Resistance
Change of tensile strength: | ≤ 15 % |
Change in elongation: | ≤ 15 % |
Resistance to Weathering
Remaining tensile strength and elongation: | ≥ 75 % (350 MJ/m2) |
Reaction to Fire
Class E | (EN 13501-1) (EN ISO 11925-2) |
Behaviour after Heat Welding of Overlaps
Shear resistance of welded seam | Break occurs outside of seam |
Service Temperature
-10 °C min. / +35 °C max.
Ambient Maximum Temperature of Liquids
+35 °C
Application
Ambient Air Temperature
+5 °C min.
SUBSTRATE QUALITY
In-situ concrete: Steel-trowel finished, clean, sound and free of standing/running water, homogeneous, free from oils and grease, dust and loose or friable particles.
Shotcrete: The profile of the shotcrete surface must not exceed a ratio of length to depth of 5 : 1 and its min. radius must be 20 centimetre. The shotcrete surface must not contain broken aggregates. Any leaks must be sealed with Sika® waterproof plugging mortar, or drained with a Sika® FlexoDrain syste,. Where necessary to achieve the desired profile/surface, apply a fine sprayed concrete layer on the shotcrete surface with a minimum thickness of 3 to 5 centimetre and aggregate diameter not exceeding 8 millimetre. Steel (girders, reinforcement mesh, anchors, etc.) must also be covered with a minimum of 4 centimetre fine sprayed concrete. The shotcrete surface must be clean (no loose stones, nails, wires, etc.).
A polypropylene geotextile (≥ 350 g/m2) or a compatible drainage layer must be installed prior to the Sikaplan® WP 1100-22 HL membrane installation. For detailed information regarding system structure please refer to the method statement.