Sikafloor® MultiDur EB-24
BROADCASTED UNICOLOUR EPOXY FLOOR COVERING
Sikafloor® MultiDur EB-24 is a slip resistant, coloured, epoxy based system, with high mechanical resistance for flooring applications. Suitable for use in hot and tropical climatic conditions.
- High wear resistance
- High mechanical resistance
- Good chemical resistance
- Liquid proof
- Gloss rough finish
- Slip resistant
System Structure
1
Primer
2
Wearing coat / Top coat
3
Wearing coat
Usage
Sikafloor® MultiDur EB-24 is used as selfsmoothing broadcasted system for concrete and cement screeds with medium to heavy wear, e.g. for:- Multi-storey and underground car parks
- Storage warehouses
- Assembly halls
- Maintenance workshops
- Garages
- Loading bays
- Plant rooms
- Wet processing areas, e.g. beverage and food industry
Advantages
- High wear resistance
- High mechanical resistance
- Good chemical resistance
- Liquid proof
- Gloss rough finish
- Slip resistant
Packaging
Please refer to the individual Product Data Sheet
Colour
Available in various colour shades.
Appearance
Slip resistant, gloss finish
System Details
APPROVALS / CERTIFICATES
- Fire classification test, Bfl-S1 according to DIN EN 13501-1, Report No.2007-B-0181/15, Germany, July 2007
- Tested according to ASTM E648-15 (Class l): Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source.
System structure
Sikafloor® MultiDur EB-24 system (~2 – 6 mm)
1. Primer | Sikafloor®-151 /-161 /-161 G |
2. Intermediate coat | Filled Sikafloor®-263 SL |
3. Top coat | |
a. Roller coat (optional) | Sikafloor-263 SL/ -264 /-264 SG |
b. Broadcast in excess with quartz sand | Sikadur®-507 (0.3 - 0.7 mm) or Sikadur®-509 (0.7 - 1.2 mm) |
c. Finishing coat | Sikafloor®-264 /-264 SG |
Composition
Pigmented epoxy resin
Nominal thickness
~2.0–6.0 mm
Shelf life
Please refer to the individual Product Data Sheet
Storage conditions
Please refer to the individual Product Data Sheet
Reaction to fire
Critical Radiant Flux: | (ASTM E648) |
Classification: Class I |
Note: Refer to test report of Sikafloor®-263 SL /-264
Chemical resistance
Refer to the chemical resistance of Sikafloor®-264 / 264 SG
Temperature resistance
Exposure* | Dry heat |
Permanent | +50 °C |
Short-term max. 7 d | +80 °C |
Short-term moist/wet heat* up to +80 °C where exposure is only occasional (i.e. during steam cleaning etc.)
*No simultaneous chemical and mechanical exposure.
Skid / slip resistance
Please refer to slip resistance of top coat (Sikafloor®-264/-264 SG)
Application
Waiting time to overcoating
Before applying Sikafloor®-263 SL/-264/-264 SG on Sikafloor®-161/161 G allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 3 days |
+20 °C | 12 hours | 2 days |
+30 °C | 8 hours | 1 day |
Before applying Sikafloor®-264/-264 SG on Sikafloor®-263 SL/-264/-264 SG allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 30 hours | 48 hours |
+20 °C | 23 hours | 25 hours |
+30 °C | 16 hours | 30 hours |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity
Applied product ready for use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~72 hours | ~6 days | ~10 days |
+20 °C | ~24 hours | ~4 days | ~7 days |
+30 °C | ~18 hours | ~2 days | ~5 days |
Consumption
Sikafloor® MultiDur EB-24 system (~ 2 – 6 mm)
Coating System | Product | Consumption |
Primer | 1 x Sikafloor®-151/-161/-161 G | ~0.3 – 0.5 kg/m2 |
Intermediate coat | Sikafloor®-263 SL filled with quartz sand | ~1.6 -2.0 kg/m2/mm Note: For more detailed information, please refer to Product Data Sheet of Sikafloor®-263 SL |
Roller coat (optional*) | Sikafloor®-263 SL /-264 /-264 SG | ~0.30 kg/m2 |
Broadcast in excess with quartz sand | Sikadur®-507 (opt.*) or Sikadur®-509 | ~1.0 - 2.0 kg/m² ~4.0 - 6.0 kg/m² |
Top coat | 1 – 2 × Sikafloor®-264 /-264 SG | ~0.25 – 0.45 kg/m2 |
*Note: For further details, please refer to General Method Statement of Sikafloor®-263 SL
Note: These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in level and wastage etc..
CLEANING