Sikafloor®-375
Sikafloor®-375 is a two part, solvent free, low viscosity, tough elastic, crack-bridging polyurethane resin. Suitable for use in hot and tropical climatic conditions.
- Good crack bridging ability
- Mechanically resistant if broadcast
- Watertight
- Easy application
- Solvent free
Usage
- For crack bridging, trafficable, slip resistant wearing layers
- For car park decks, garage floors and bridges
Advantages
- Good crack bridging ability
- Mechanically resistant if broadcast
- Watertight
- Easy application
- Solvent free
Packaging
Part A | 24.0 kg containers |
Part B | 6.0 kg containers |
Part A+B | 30.0 kg ready to mix units |
Colour
Beige
Product Details
SUSTAINABILITY
LEED rating:
Sikafloor®-375 conforms to the requirements of LEED EQ Credit 4.2: Low-Emitting Materials: Paints & Coatings
EPA Reference Test Method 24 VOC Content < 100 g/l
APPROVALS / CERTIFICATES
- Coating for concrete protection according to EN 1504-2:2004 and the EN 13813:2002
- Reaction to Fire classification according to EN 13501-1. Test institute Hoch Report No. KB-Hoch-101213 .
Composition
Polyurethane
Shelf life
12 months from date of production
Storage conditions
The packaging must be stored properly in original, unopened and undamaged sealed packaging, in dry conditions at temperatures between +5°C and +30°C. Protect from direct sunlight, heat and moisture.
Density
Part A | ~1.66 kg/l |
Part B | ~1.24 kg/l |
Mixed resin | ~1.55 kg/l |
All Density values at +23°C
Solid content by weight
~100 %
Solid content by volume
~100 %
Tensile Strength
~11 N/mm² (14 days / +23 °C) | (DIN 53504) |
Application
Mixing Ratio
Part A : part B = 80 : 20 (by weight)
Ambient Air Temperature
+10 °C min. / +30 °C max.
Relative Air Humidity
80 % r.h. max.
Dew Point
Beware of condensation!
The substrate and uncured floor must be at least 3 °C above dew point to reduce the risk of condensation or blooming on the floor finish.
Substrate Temperature
+10 °C min. / +30 °C max.
Substrate Moisture Content
< 4 % pbw moisture content.
Test method: Sika®-Tramex meter, CM - measurement or Oven-dry-method.
No rising moisture according to ASTM (Polyethylene-sheet).
Pot Life
Temperatures | Time |
+10 °C | ~60 minutes |
+20 °C | ~25 minutes |
+30 °C | ~15 minutes |
Curing Time
Before overcoating Sikafloor®-375 allow:
Substrate temperature | Minimum | Maximum |
+10 °C | 24 hours | 48 hours |
+20 °C | 15 hours | 24 hours |
+30 °C | 8 hours | 16 hours |
Times are approximate and will be affected by changing ambient conditions particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot traffic | Light traffic | Full cure |
+10 °C | ~24 hours | ~72 hours | ~7 days |
+20 °C | ~12 hours | ~30 hours | ~5 days |
+30 °C | ~5 hours | ~24 hours | ~4 days |
Note: Times are approximate and will be affected by changing ambient conditions
Consumption
~1.55 kg/m2/mm. For further consumption details please refer to the respective System Data Sheet.
Note: These figures are theoretical and do not allow for any additional material required due to surface porosity, surface profile, variations in level or wastage etc..
MIXING
Prior to mixing, stir part A mechanically. When all of part B has been added to part A, mix continuously for 2 minutes until a uniform mix has been achieved.
For the addition of quartz sand: When parts A and B have been mixed, add the quartz sand 0.1 - 0.3 mm and mix for a further 2 minutes until a uniform mix has been achieved. To ensure thorough mixing pour materials into another container and mix again to achieve a consistent mix. Over mixing must be avoided to minimise air entrainment.
Mixing Tools:
Sikafloor®-375 must be thoroughly mixed using a low speed electric stirrer (300 - 400 rpm) or other suitable equipment.
APPLICATION
Prior to application, confirm substrate moisture content, relative humidity and dew point.
Sikafloor®-375 is poured and spread evenly with a serrated / notched trowel. Then, level and remove entrained air with a spiked roller and broadcast with quartz sand, at first lightly and then to excess.
CLEANING OF EQUIPMENT
Clean all tools and application equipment with Thinner C immediately after use. Hardened and/or cured material can only be removed mechanically.