Contact us if document is not available
SikaSeal®-490 SL
(former MSeal SL 190)
High performance, self-leveling, jet fuel and chemical resistant joint sealant for runways, pavements and industrial environment
SikaSeal®-490 SL is a high performance, two-component specially engineered sealant, based on hybrid polymer chemistry. It has excellent hydrolytic, jet fuel and UV resistant properties.
- Excellent hydrolytic resistance properties
- Jet fuel resistant
- Cold-applied
- High resilience
- Chemical resistant
- Hydrocarbon resistant
- High durability
- Weather and UV resistant
- Suitable for concrete, asphalt and metal substrate
Contact us if document is not available
Usage
- Airport runways and fueling zones
- Highway and bridges
- Driveways and loading docks
- Stadiums
- Chemical plants
- Oil and gas terminals, secondary containments zone
- Warehouse and garage
Advantages
- Excellent hydrolytic resistance properties
- Jet fuel resistant
- Cold-applied
- High resilience
- Chemical resistant
- Hydrocarbon resistant
- High durability
- Weather and UV resistant
- Suitable for concrete, asphalt and metal substrate
Packaging
5 L kit | 18 L kit |
Colour
Dark grey
Product Details
CERTIFICATES AND TEST REPORTS
SikaSeal®-490 SL complies to:
- ASTM D 3137: Standard test method for hydrolytic stability.
- BS EN 14188-2: Joint filler and sealant for cold applied sealant (BS EN 14187-5: Cold applied joint sealants - test method for the determination of the resistance to hydrolysis).
- BS 5212-1: Cold applied joint sealant systems for concrete pavements.
- U.S. Federal Specification SS-S200E: Sealants, joint, two component, jet blast resistant, cold applied for portland cement concrete pavement.
- ASTM C 920 Type M, Grade P, Class 25, Use T, NT and M.
- BS EN ISO 9046: Determination of adhesion/ cohesion properties of sealants at constant temperature.
- BS EN ISO 9047: Determination of adhesion/ cohesion properties of sealants at variable temperatures.
Shelf life
SikaSeal®-490 SL has a shelf life of 12 months from the date of production, if it is stored in undamaged, original, sealed packaging, and if the storage conditions are met.
Storage conditions
SikaSeal®-490 SL shall be stored in dry conditons, where it is protected from direct sunlight and at temperatures between +5°C and +25°C.
Density
1.59 g/cm³ (mixed) | (ASTM D 1475) |
Shore A hardness
~26
Tensile strength
~0.8 N/mm2 | (ASTM D 412) |
Elongation at break
~550 % | (ASTM D 412) |
Movement capability
±25 % | (ASTM C 719) |
Tensile adhesion strength
Concrete | Metal | Asphalt |
~1.8 N/mm2 | ~1.1 N/mm2 | ~1.5 N/mm2 |
Chemical resistance
Resistance to fuel immersion (% mass change) | Pass | SS-S-200E BS 5212-1 |
Application
Ambient air temperature
+5°C to +45°C, min. 3°C above dew point temperature
Substrate temperature
+5°C to +45°C, min.
Tack free time
< 3 h | (ASTM C 679) |
Applied product ready for use
Pedestrian walking | Vehicle movement |
12 - 16 h | 24 h |
Consumption
Joint length [m] per 1 L | Joint width (mm) | Joint depth (mm) |
16 | 10 | 6 |
8 | 15 | 8 |
5 | 20 | 10 |
3 | 25 | 12 |
2 | 30 | 15 |
1.6 | 35 | 17 |
1.2 | 40 | 20 |
These are approx. consumption and may vary based on actual site conditions.
SUBSTRATE PREPARATION
- All surfaces must be clean, dry and free from any loosely adhering particles.
- Check the joints edges for soundness and if found weak cut recess and fill up with suitable repair mortar.
- Correct joint depth can be established by inserting closed cell polyethylene backing rod tightly into the joint.
- When the joints have been filled with fiber filled board, this must be raked back to the required depth. Use bond breaker tape over the backer material.
- Protect surfaces with masking tape.
MIXING
- Mix and use one complete unit at a time. Do not split the units.
- Add comp. B into the comp. A pail. Mix the product thoroughly with a mixing paddle fitted to an electric hand drill, not exceeding 500 rpm, to avoid air entrapment.
- Mix for approximately 5 - 10 minutes until a smooth, even consistency is achieved.
- The sides and base of the container should be periodically scraped down to ensure all of the comp. B is completely blended with the comp. A.
- Failure to mix correctly will result in bubbles, uncured sealant and lumps.
- Once the product is mixed it should be used immediately.
APPLICATION
- SikaSeal®-490 SL must always be applied to surface primed with Sika® Primer-190 or Sika® Primer-117 MS.
- SikaSeal®-490 SL should be applied between 2 hours to 6 hours at 23⁰C of primer application.
- If joint is not sealed within recommended time, the joint must be re-primed.
- If the joint is not sealed or re-primed within 24 hours, the cured primer should be removed and joint primed again.
- The mixed SikaSeal®-490 SL maybe poured directly from the tin or can be loaded into a gun for application.
- For detailed, recommended surface preparation and installation procedures, refer to SikaSeal®-490 SL method statement.
CLEANING OF EQUIPMENT
- Application equipment should be cleaned immediately with Sika®Colma Cleaner, acetone or any suitable cleaning solvent after use.