Contact us if document is not available
SikaSwell® A (AE)
(former MSeal 910)
Hydrophilic swellable joint sealing profiles
SikaSwell® A (AE) is a rectangular acrylic sealing profile. It swells in contact with water to seal all types of construction joints and penetrations in concrete structures.
- Highly economical joint sealing solution
- Unique properties, fills the small cracks and voids
- Versatile solution for joints and details
- Permanently water resistant (wet & dry cycles)
- Resistant to various chemical substances
- Easy and fast to apply
- Can be applied on different substrates
- Available in different sizes
Contact us if document is not available
Usage
Joint sealing:- Construction joints
- Pipe and steel work penetrations through walls and floor slabs
- Around all types of penetrations and connection joints
- Construction joints in cable ducts
Advantages
- Highly economical joint sealing solution
- Unique properties, fills the small cracks and voids
- Versatile solution for joints and details
- Permanently water resistant (wet & dry cycles)
- Resistant to various chemical substances
- Easy and fast to apply
- Can be applied on different substrates
- Available in different sizes
Packaging
Single rolls packed in vacuum foil. Multiple single rolls packed in cardboard boxes. Refer to current price list for packaging variations.
Product Details
SUSTAINABILITY
- Conforms with LEED v4 MR credit: Building product disclosure and optimization — Material ingredients (option 2)
Composition
Acrylic polymer
Shelf life
12 months from the date of production
Storage conditions
The product must be stored in original, unopened and undamaged packaging in dry conditions at temperatures between +5°C and +35°C. Always refer to packaging.
Density
~1.50 kg/l (at +23°C)
Dimensions
Type | Width | Height | Length |
SikaSwell® A (AE) 2005 | 20 mm (±10 %) | 5 mm (±5 %) | 20 m |
SikaSwell® A (AE) 2010 | 20 mm (±10 %) | 10 mm (±5 %) | 10 m |
System structure
Adhesive | SikaSwell® S-2 |
Swelling profile | SikaSwell® A (AE) |
Service temperature
Maximum | +50°C |
Minimum | -20°C |
Change of volume
Time | Demineralised water |
1 day | ~50 % |
7 days | ~130 % |
30 days | ~150 % |
Note: Swelling properties in saline water will be reduced and delayed. Use SikaSwell® A Maritim version.
Note: In a totally dry state the Product shrinks to its original dimensions. The product then expands again upon further contact with water.
Swelling pressure
The pressure developed by the material depends on the stiffness of the surrounding concrete structure, which is influenced by the concrete quality, voids, gaps and other weaknesses.
Note: In an ideal concrete structure the material can develop a swelling pressure of >10 bar.
Application
Ambient air temperature
Maximum | +35°C |
Minimum | +5°C |
Substrate temperature
Maximum | +35°C |
Minimum | +5°C |
Substrate moisture content
Dry or matt damp. Do not apply in construction joints with existing standing water
SUBSTRATE QUALITY
The substrate must be sound, clean, dry or matt damp, free from all surface contaminants that could impair the adhesion.
SUBSTRATE PREPARATION
EXISTING CONCRETE
Rough surfaces are susceptible to leaking. If the surface roughness cannot be leveled with SikaSwell® S-2 the roughness shall be leveled with an appropriate Sika leveling mortar or by mechanical treatment, before the SikaSwell® S-2 and SikaSwell® profile is applied.
|
|
FRESHLY CAST CONCRETE
Freshly cast concrete can be smoothed with a batten where SikaSwell® S-2 is to be placed.
APPLICATION
IMPORTANT
Concrete cover
Insufficient concrete cover, low density concrete or voids will prevent the SikaSwell® A (AE) from developing its waterproofing function.
- Place the SikaSwell® profile in the centre of the concrete structure.
- In reinforced concrete maintain a minimum cover of 8 cm on both sides.
- In unreinforced concrete maintain a minimum cover of 15 cm on both sides.
|
|
Sealant with SikaSwell® A (AE)
- Apply SikaSwell® S-2 adhesive in a narrow bed (size of triangular section ~12 mm tall and ~12 mm wide ) onto the prepared substrate. Extrude enough material to level the roughness of the substrate.
- Press the SikaSwell® A (AE) firmly into the fresh applied SikaSwell® S-2. Place the SikaSwell® A (AE) within a maximum of 30 minutes (+23 °C / 50 % r.h.).
- Ensure full and continuous contact between the SikaSwell® S-2 and both the SikaSwell® A (AE) and the substrate is achieved.
- Allow SikaSwell® S-2 to harden minimum 12 hours before placing concrete. For pouring height > 50 cm, SikaSwell® S-2 must harden for at least 24 hours before placing concrete.
- Protect the SikaSwell® S-2 and the SikaSwell® A (AE) against water (for example, rain) until the concrete is placed.
- During placement compact the fresh concrete well around the SikaSwell® A (AE) to achieve dense concrete without any honeycombing or voids.
CLEANING OF EQUIPMENT
Clean all tools and application equipment immediately after use with Sika® Colma Cleaner. Hardened material can only be removed mechanically.