Since many decades Sika has been a reliable partner with waste water treatment plant contractors supplying products and systems on all continents. Sika has shown the industry we are a partner, they can trust. The products and systems used in new waste water treatment plants and retrofitted structures are thoroughly tested in Sika laboratories before being independently checked. Sika materials are further proven by long term site testing to withstand the harsh conditions in the real environment.

Systems Plus Knowhow

Waste water treatmant plant in Zurich, Switzerland

Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder Sika Solutions for sewers and waste water treatment plants lorem possum iposssom opossum elephant monkey placeholder  

Exposures for Sewers

Damage on Sewers and Water Tanks
Damages at the bottom

Heavy abrasion and erosion of the concrete and prefabricated elements are often found at the bottom of the sewers. In general rules, these elements shall be replaced and reassembled properly by bonding them in place with an epoxy adhesive. In the case of the concrete substrate, the erosion can be repaired with a high abrasion resistant mortar that will increase the service life of the substrate

Damage on Sewers and Water Tanks
Localized defects of the concrete

Lateral walls and the crown often show localized defects of the concrete and some- times defects due to the corrosion of the reinforcement. After appropriate preparation, these defects can be repaired using sulfate resistant repair mortars.

Damage on Sewers and Water Tanks
Full degradation of the concrete surface

The resistance of tamped concrete against a strong water current is generally not enough and often the full surface of the concrete is eroded. It is recommended in these zones to proceed with a full resurfacing.

Damage on Sewers and Water Tanks
Cracks with water leaks

Due to shrinkage or settlements, concrete in sewers often cracks. These cracks need
to be fi lled in order to prevent leakage of pollutant to surrounding ground water. It is often necessary to use expanding materials to fi ll these cracks.

Damage on Sewers and Water Tanks
Damages at the crown

Exposed tamped concrete surfaces show very low resistance against carbonation and the aggressive substances contained in the waste water. Therefore, these surfaces can be protected using EpoCem® technologies which are extremely resistant and watertight against urban waste water.

At the crown area, the structure can be protected against condensation water using a hydrophobic impregnation. Additionally, the aerial part of the sewer can suffer from biogenic corrosion or microbial induced corrosion (MIC). To repair and protect these areas a 100% Calcium Aluminate Mortar must be used.

General Refurbishment Considerations

Before defining the repair and protection strategy, the specific sewage treatment plant requirements on refurbishment must be considered. These requirements can have an important influence in determining the correct design, planning and construction procedures, together with the future maintenance works necessary for the sewage treatment plant. Examples of these project related requirements are outlined below.

  • Durability
  • Duration of closure / Downtime
  • System compatibility
  • Total life cycle costing
  • Exposures / Site Conditions
  • Ecology
Waste water treatment plant in Wroclaw in Poland

Refurbishment Solutions for Waste Water Treatment Plants

1. Screening Channel

In a large treatment plant, the removal of large objects is automatically performed in the screening channel.

Abrasion and erosion

Problem

In waste water treatment plants, erosion is mainly due to abrasion or by chemical attack. Erosion damage results from the abrasive effect of waterborne silt, sand, gravel, and other debris being circulated over a concrete surface during operation. The compounds present in hardened Portland cement are attacked by the aggressiveness (low pH) of the waste water.  

Sika Solution

Sika MonoTop®-3400 Abraroc

Chemical attacks

Problem

Chemical attacks, depending on the aggressiveness of the waste or industrial water.  

Sika Solution

Sikagard®-720 EpoCem®
Sika® Poxitar F (or Sikagard®-63 N)

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete.

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Microbial induced corrosion (MIC) in covered areas

Problem

Damage in concrete due to microbial induced corrosion (MIC) in covered areas where the sewage is in a turbulent flow.

Sika Solution

Sika MonoTop®-4400 MIC

Construction elements of cleaning waste water - Illustration

2. Grit, Fat and Grease Removal Chamber

In some plants, pre-treatment may include a grit channel where the waste water velocity is adjusted to allow settlement of the sands/grits or other hard particles. Sands/grits must be removed as they may damage pumps or other equipment. Fat and grease removal is generally done in a large plant in the primary settlement tank using mechanical surface skimmers.

Abrasion and erosion

Problem

Abrasion and erosion due to sand, grit or other particles.

Sika Solution

Sika MonoTop®-3400 Abraroc

Chemical attacks

Problem

Chemical attacks depending on the aggressiveness of the waste or industrial water.

Sika Solution

Sikagard®-720 EpoCem®
Sika® Poxitar F (or Sikagard®-63 N)

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete. Very often in waste water treatment, joints sealed with average sealant fails due to the lack of chemical resistance to these products. Instead of proceeding to the full removal of the failed joint, Sika has developed a joint system that can be applied over the original failed material.
The Sikadur-Combifl ex® SG system is the second generation development of the globally proven Sikadur-Combifl ex® with even improved performance such as advanced adhesion properties. The unique system consists of the Sikadur Combiflex® SG tape and the Sikadur® adhesives. It is widely used as joint waterproofing in watertight concrete structures.

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Microbial induced corrosion (MIC) in covered areas

Problem

Microbial induced corrosion (MIC) in covered areas where the sewage is in turbulent flow

Sika Solution

Sika MonoTop®-4400 MIC

Construction elements of cleaning waste water - Illustration

3. Primary Sedimentation Tanks

In the primary sedimentation tank, sewage flows through large tanks, commonly named “primary clarifiers” or “primary sedimentation tanks”. These tanks are equipped with mechanically driven scrappers that drive the collected sludge towards a hopper.

Chemical attacks and damaged waterproofing

Problem

Chemical attacks depending on the aggressiveness of the waste or industrial water.

Sika Solution

Sikagard®-720 EpoCem®
Sika® Poxitar F (or Sikagard®-63 N)

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Damaged concrete and steel reinforcement corrosion

Problem

Abrasion and erosion due to sand, grit or other particles.

Sika Solution

Sika MonoTop®-412 NFG
SikaTop® Armatec®-110 EpoCem®
Sika MonoTop®-2400 Reseaux

Mechanical abrasion

Problem

Heavy abrasion on the rolling pad of the scrapper.

Sika Solution

Sikadur®-42
Sika® Icosit®-KC 330 FK

Construction elements of cleaning waste water - Illustration

4. Secondary Sedimentation Plant

Secondary treatment is intended to degrade further the organic content of sewage water originating from human waste, soap, detergent, etc. Most of the plants treat the sewage using aerobic biological processes.

Erosion

Problem

Erosion due to water flow

Sika Solution

Sikagard®-720 EpoCem®

Chemical attacks

Problem

Chemical attacks, depending on the aggressiveness of the waste water.

Sika Solution

Sikagard®-720 EpoCem®
Sika® Poxitar F (or Sikagard®-63 N)

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3
Sikafl ex® TS Plus

Corrosion

Problem

Steel reinforcement corrosion due to reduced concrete cover.

Sika Solution

Sika MonoTop®-412 NFG
SikaTop® Armatec®-110 EpoCem®
Sika MonoTop®-2400 Reseaux 

Construction elements of cleaning waste water - Illustration

5. Aerated and anoxic biological tanks

Biological tanks are designed to substantially degrade the biological content of the sewage. These biological contents are originated from human waste, soap, and detergents.

Chemical attacks

Problem

Chemical attacks depending on the aggressiveness of the waste or industrial water.

Sika Solution

Sikagard®-720 EpoCem®
Sika® Poxitar F (or Sikagard®-63 N)

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete.

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Concrete Spalling

Problem

Concrete spalling due to reinforcement steel corrosion.

Sika Solution

Sika MonoTop®-412 NFG
SikaTop® Armatec®-110 EpoCem®
Sika MonoTop®-2400 Reseaux 

Construction elements of cleaning waste water - Illustration

6. Filtration Beds

In the filtration bed, the treated water flows through various layers of sand beds for final filtration before being discharged in the environment. Filters are periodically cleaned using air and clean water at the counter stream. The cleansing water is then pumped back to the aeration basin for retreatment.

Abrasion

Problem

Abrasion and erosion due to sand, grit or other particles.

Sika Solution

Sika MonoTop®-3400 Abraroc

Damaged waterproofing

Problem

Chemical attacks depending on the aggressiveness of the waste or industrial water.

Sika Solution

Sikagard®-720 EpoCem®

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete.

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Construction elements of cleaning waste water - Illustration

7. Digestion Tanks

The sewage sludge digestion tank is where the sludge is stabilized, reduced in volume, made innocuous through the process of dissolving organic substance with the help of anaerobic bacteria and finally, where energy is recovered.

Abrasion and erosion

Problem

Abrasion and erosion due to sand, grit or other particles.

Sika Solution

Sika MonoTop®-3400 Abraroc

Chemical attacks

Problem

Concrete or steel above the sludge may suffer heavy attack due to the formation of the sulfuric acid. Additional stress is caused by the elevated temperature originating from the biological process. Downtimes always create problems and difficulties for the owners, as well as the loss of money. Sika offers solvent-free, high build coating systems that can be applied in one layer on a well-prepared surface. Therefore, downtimes can be minimized without the reduction of protective properties.

Sika Solution

Sika® Permacor® 3326 EG H
Sikalastic®-844 XT, / -8440
Sikaflex® PRO-3

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete.

Sika Solution

Sikadur-Combifl ex® SG

Construction elements of cleaning waste water - Illustration

8. Gasometers

Within the process of biological deterioration in the biological tank or the digestion tank, biogas (methane, CO²) will be produced and be stored in gasometers. These gasometers are generally built-in steel. Biogenic sulfuric acid is highly aggressive to steel. Additional stresses are caused by the elevated temperature.

Steel corrosion

Problem

Sika provides a large range of extensively tested products in the field of corrosion protection. Sika offers products for the protection of new structures on-site or for shop applications. For maintenance works, Sika offers a surface tolerant primer allowing the application of the corrosion protection without sandblasting the surface, meaning no plant shut down is necessary. UV-resistant topcoats, available in almost all RAL color shades, give the possibility for aesthetic designs.

Sika Solution

Sika® Icosit® 6630 System
SikaCor® EG System

Cracks, untight joints

Problem

Leakage and risk of pollution due to cracks, untight joints or damaged concrete.

Sika Solution

Sikadur-Combifl ex® SG
Sikaflex® PRO-3

Construction elements of cleaning waste water - Illustration

9. Service Building

Most waste water treatment plants have a technical service building. External surfaces of the building as well as of the above-ground tanks are exposed to weathering and therefore often need protection.

Flooring

Problem

In these technical buildings, chemicals are handled. Therefore, the floors in the chemical storage area also need protection.

Sika Solution

Sikafloor®- 381
Sikafloor®-21 PurCem

Roofing

Problem

Roofs in the buildings (technical and office) of the sewage treatment plants may require waterproofing.

Sika Solution

SikaPlan® PVC or FPO membrane
Sikalastic® liquid applied membrane

Technical service building of a waste water plant

Sika’s Experts Provide Assistance to Benefit your Business

World Map

Local Contact

Contact a Sika expert near you for technical support and locally available products and systems.

Global Support

Contact Sika's global representative in case you need our support in an international project.